Parameter
Minimum - Maximum draught
Fuel consumption
Smoke mass flow rate
Efficiency
Nominal output
Power range
Average CO concentration at 13% of O2
NOx concentration at 13% of O2
OGC concentration at 13% of O2
Particle concentration at 13% of O2
Medium draft (trial)
Net weight
Maximum authorized load (fuel)
Reload height
Logs length
Minimum flue height
Ø Flue duct
Ø Air inlet
Ø Air outlet
Safety distances
(back)
Safety distances
(sides)
Safety distances
(frontal)
Fireplace room ventilation
Electrical wiring connection
Fan airflow (unit)
Fan output (unit)
Minimum safety distance to the air outlets
Average temperature of smoke
Type of combustion
Flue liner
Fuel
Humidity fuel logs
Certification year
Certificate number
1.2 Breakdown of delivery components
(
Make sure you have all the components described below in relation to the picture on section II of the ANNEXED document)
1. Fireplace's body.
2. Heat-resistant spray paint for touch-ups.
3. Fire grate.
4. Heat-resistant glove.
5. 2x Outlet hot air connector (ARc 50V, ARc 50V + Plus 150, ARc 65, ARc 65 +Plus 150, ARc 70, ARc 70 + Plus 150, ARc
70A, ARc 70A + Plus 150, ARc 70C, ARc 70C + Plus 150). 4x Outlet hot air connector (ARc 80, ARc 80 + Plus 180, ARc
100R, Arc 100R + Plus180, ARc 100, ARc 100 + Plus 180)
6. Cleaning cloth for metal painted parts
7. Exterior air inlet kit. (Exterior air inlet connector, connector support, tubular joint, metallic anchor, screws and nuts)
8. Tool for handling registers and opening door.
9. 8x screws (ARc 50V, ARc 50V + Plus 150, ARc 65, ARc 65 +Plus 150, ARc 70, ARc 70 + Plus 150, ARc 70A, ARc 70A +
Plus 150, ARc 70C, ARc 70C + Plus 150) | 16x screws (ARc 80, ARc 80 + Plus 180, ARc 100R, Arc 100R + Plus180, ARc
100, ARc 100 + Plus 180) to install outlet hot air connectors.
10. Documentation bag: output declaration, energy label, guarantee, technical sheet, and installation and operating
characteristics manual.
11.
Optional: + Plus 150 (ARc 50 + Plus 150 | ARc 65 + Plus 150 | ARc 70 + Plus 150 | ARc 70A + Plus 150 | ARc 70C + Plus
150) | + Plus 180 (ARc 80 + Plus 180 | ARc 100R + Plus 180 | ARc 100 + Plus 180)
12.
Packaging. The wooden pallet can be used as fuel or recycled. Other packaging items must be recycled or disposed of
13.
Draft limiter
1.3 Diagram of the equipment's measurements
See the ANNEXED document, section I
2. REQUIREMENTS PRIOR TO INSTALLATION
ALL LOCAL STANDARDS, INCLUDING NATIONAL AND EUROPEAN REGULATIONS MUST BE COMPLIED WITH
UPON INSTALLATION OF THE EQUIPMENT.
THE INSTALLATION MUST BE PERFORMED BY A PROFESSIONAL. FAILURE TO COMPLY WITH THIS CLAUSE SHALL
EXONERATE THE MANUFACTURER FROM ANY RESPONSIBILITY.
2.1 Ground. Make sure the ground where the appliance will be placed is able to support the weight of the device. If not, you will need
a load spreading plate for the equitable distribution of the equipment's weight. In case of doubt, please consult a specialist.
2.2 Flue liner. It is mandatory to have a smoke-tight Flue liner going from the connecting point of the base to the outside in observation
of the smoke pipe diameter. The good condition and suitability of this smoke pipe must be certified by a professional and
must also observe the relevant national regulations. This flue liner must be T400 and G type should not be shared with other
devices (see Table 1.1 Technical specifications). In cases of too much draught, when the duct exceeds 7 meters in length, or the
measurement exceeds 20 Pa, the draft must be adjusted. To do this, use the second part of the baffle plate, to install it follow the
steps: "D.9" to "D.12" or adjust the air intake through the grille go to Section 4.4.1 Primary Registrer.
11
ARc 100R
11 -13 Pa
3,1 kg/h
9,9 g/s
77 %
10,5 kW
7,5 - 12,5 kW
0,099 %
107 mg/Nm3
66 mg/Nm3
24 mg/Nm3
11 Pa
121 kg
4,5 kg
200 mm
400 mm
4000 mm
180 mm
100 mm
120 mm
150 mm
150 mm
1000 mm
(entry - exit)
450 cm
2
322º C
2022
1880-CPR-039-004-21
Model
ARc 100R
+Plus 180
11 -13 Pa
2,8 kg/h
9,7 g/s
85,3 %
11 kW
7,5 - 12,5 kW
0,09 %
106 mg/Nm3
59 mg/Nm3
23 mg/Nm3
8,6 Pa
169 kg
4,5 kg
200 mm
400 mm
4000 mm
180 mm
100 mm
120 mm
150 mm
150 mm
1000 mm
450 cm
2
Silicone hose 3*wire of 1.5 mm
135 m
3
/h
20 W
250 mm
211,3 ºC
INTERMITENT
NOT SHARED
NATURAL WOOD
12-20 % - two years under cover
2022
1880-CPR-041-006-21
1880-CPR-39-21
ARc 100
ARc 100
+Plus 180
11 -13 Pa
11 -13 Pa
3,18 kg/h
3,19 kg/h
9,9 g/s
9,7 g/s
79,6 %
86,2 %
11,1 kW
12,1 kW
7,5 - 13 kW
7,5 - 13 kW
0,091 %
0,09 %
107 mg/Nm3
101 mg/Nm3
66 mg/Nm3
59 mg/Nm3
12 mg/Nm3
18 mg/Nm3
11,6 Pa
11,4 Pa
143 kg
160,9 kg
5 kg
200 mm
200 mm
600 mm
600 mm
4000 mm
4000 mm
180 mm
180 mm
100 mm
100 mm
120 mm
120 mm
150 mm
150 mm
150 mm
150 mm
1000 mm
1000 mm
450 cm
2
450 cm
2
279ºC
196,8ºC
2021
2019
1880-CPR-041-21
4 kg
2