All manuals and user guides at all-guides.com
Ducted mode air exhaust system
CAUTION
Risk of fire! To reduce the risk of fire, use metal ductwork only.
1. Decide where the ductwork will run between the
hood and the outside.
2. A straight, short duct run will allow the hood to
perform most efficiently.
3. Long duct runs, elbows, and transitions will
reduce the performance of the hood. Use as
few of them as possible. Larger ducting may be
required for best performance with longer duct
runs.
4. Attach an adequate length of Ø 150 mm round
duct to the air outlet adapter.
5. The air must not be discharge into a flue that
is used for exhausting fumes from appliances
burning gas or other fuels. Regulations
concerning the discharge of air have to be
fulfilled.
6. Install a roof/wall cap. Connect round metal
ductwork to cap and work back towards
hood location. Use duct tape to seal the joints
between ductwork sections.
Recirculation Mode
CAUTION
Risk of fire! Do not use plastic or rigid metal ducting.
1. Install the charcoal filter on (see section "Cleaning and Maintenance").
2. Please note that the air will flow out from the two grids on the two sides of the
decorative chimney bottom.