Télécharger Imprimer la page

Continental Fireplaces CEFV38H Instructions D'installation Et D'opération page 4

Foyer électrique

Publicité

Les langues disponibles

Les langues disponibles

4
1.1
DIMENSIONS
FRONT VIEW
EN
17" [432mm]
1.2
LISTING APPROVALS
This appliance has been tested in accordance with the CSA Standards for fi xed and location-dedicated electric
room appliances in the United States and Canada. If you need assistance during installation, please contact
your local dealer.
NOTE: This appliance must be electrically wired and grounded
in accordance with local codes or, in the absence of local codes,
with National Electric Code ANSI/NFPA 70-latest edition in the
United States or the Canadian Electric Code, CSA C22.1 in
Canada.
W415-1523 / 06.22.15
21"
[555mm]
38"
[965mm]
12" [305mm]
SIDE VIEW
1 1/8"
[28mm]
[89mm]
32"
[825mm]
JUNCTION
BOX
6" [152mm]
TOP VIEW
13" [320mm]
3 1/2"
20°
17" [432mm]
BACK VIEW
12" [305mm]
11" [280mm]
Model Number
CEFV38H
Description
Wall-Mount
Appliance
Voltage
120V AC~60Hz
Watts
Max 1500W
Amps
15 AMP Grounded
Circuit
Appliance Width
17" (432mm)
Appliance Height 38" (965mm)
Appliance Depth
6" (152mm)
Net Weight
14.5kg (32lbs)
Gross Weight
17kg (37lbs)