Cable Selection
Generator
10 A
Socket Type
Recommended
Cable Cross
Section
0 to
4
10
50 m
Length
of
51 to
100 m 10
7
Cable
Used
101 to
10
7
150 m
1
This cable length is maximum permitted
1
length, and must not be exceeded.
Installation method=cables on raceway
or non-drilled tablet/Permitted drop in
voltage=5%/Multi-core conductors/Cable
type PVC 70°C (e.g. H07RNF)/Ambient
temperature=86° F (30° C).
Maintenance Instructions
Accidental Starts can cause
severe injury or death.
Disconnect and ground spark
plug lead(s) before servicing.
Safety is an obligation of owner. Periodic inspection, adjustment and lubrication will keep your
generator in safest and most efficient condition possible. Most important points of generator
inspection, adjustment, and lubrication are explained on following pages.
Maintenance Schedule
First 25 Hours or Annually
● Service/replace precleaner (if equipped).
Every 100 Hours or Annually
● Change oil.
● Replace air cleaner element (AA).
● Remove and clean shrouds and cooling areas.
Every 200 Hours
1
● Replace unique Electronic Fuel Injection (EFI) fuel filter.
Every 200 Hours or Annually
● Change oil and filter (V).
Every 500 Hours or Annually
● Replace spark plugs (X) and set gap.
Perform these procedures more frequently under severe, dusty, dirty conditions.
1
6
All manuals and user guides at all-guides.com
16 A
32 A
6
9
10
7
10
7
25
3
16
5
35
2
WARNING
Before working on generator or equipment,
disable engine as follows: 1) Disconnect spark
plug lead(s). 2) Disconnect negative (–) battery
cable from battery.
Do not allow children to operate generator.
1
1
1
1
KohlerPower.com
Auto Idle
NOTE: Auto Idle will only function when unit is
on 120V function.
ON Position. When Auto Idle (K) switch is
in ON position, Auto Idle (K) controls engine
speed according to connected load. Results are
better fuel consumption and less noise.
OFF Position. When Auto Idle (K) switch is in
OFF position, engine runs at rated rpm (3,600
rpm) regardless of whether there is a load
connected or not.
NOTE: Turn Auto Idle to OFF when unit is using
240V configuration.
Stopping
1. Disconnect electrical devices and allow
engine to run without any load for 1-2
minutes.
2. Turn MODYS (B) key to OFF position
(generator stops).
3. Close fuel valve (P).
Engine Speed
NOTE: Do not tamper with governor setting to
increase maximum engine speed.
Overspeed is hazardous and will void
warranty.
34 590 01 Rev. A