Pre-Start Checklist
1. Ensure generator is at least 3.3 ft. (1 m) from
building or other equipment and not covered
with any material.
2. Refer to all warning labels prior to starting.
3. Check oil level. Add oil if low. Do not overfill.
4. Check fuel level. Add fuel if low. Stop
refueling when indicator reaches F (full)
level. Check fuel system components and
lines for leaks. Never refuel while unit is
running.
5. Check starter battery (S).
6. Ground generator.
7. Check that air cleaner components and all air
inlets are unobstructed, equipment covers,
and guards are in place and securely
fastened.
8. Ensure electrical devices (load) are not
connected to generator.
Starting
Rotating Parts can cause severe
injury.
Stay away while generator is in
operation.
Keep hands, feet, hair, and clothing away
from all moving parts to prevent injury. Never
operate generator with covers, shrouds, or
guards removed.
NOTE: Auto Idle (K) switch must be in OFF
position when using electric devices
that require a large starting current,
such as a compressor or a submersible
pump. Auto Idle (K) controls engine
speed according to connected load.
Results are better fuel consumption
and less noise.
NOTE: MODYS (B) automatically performs 5
start-up attempts.
34 590 01 Rev. A
All manuals and user guides at all-guides.com
WARNING
KohlerPower.com
1. Turn main AC circuit breaker (E) OFF.
2. Turn fuel valve (P) ON.
3. Turn MODYS (B) key to ON position.
4. Press START button on MODYS (B).
5. Test GFCI receptacles (G).
Cold Weather Starting
1. Use proper oil for temperature expected.
2. Disengage all possible external loads.
3. Use fresh winter grade fuel. Winter grade
fuel has higher volatility to improve starting.
Operation
Hazardous Voltage.
Backfeed to utility system can
cause property damage, severe
injury, or death.
Never plug a portable generator directly into
a building outlet.
If generator is used for standby power,
have a certified, licensed electrician install
an automatic transfer switch to prevent
inadvertent interconnection of standby and
normal sources of supply.
When running speed of generator has
stabilized (approximately 3 minutes):
1. Check that circuit breakers (E) are pushed in.
Press if necessary.
2. Connect appliances to be used to electrical
sockets (G, L, M and N) of generator.
3. Hour meter (A) shows number of hours that
generator has worked.
Angle of Operation
Do not operate this engine exceeding maximum
angle of operation; see specification table.
Engine damage could result from insufficient
lubrication.
EN
WARNING
5