CAUTION
Refer to the battery manufacturer's safety instructions for proper battery
installation and operation.
NEUTRAL FLOATING: Do not connect to the inverter any AC products
whose neutral conductor is connected to the ground.
THE ELECTRICITY GENERATED BY THE INVERTER IS MODIFIED SINE
WAVE. Do not use the inverter to power the following devices:
Small appliances such as rechargeable flashlights, some razors,
and some rechargeable night lights that plug into a wall outlet for
recharge.
Some battery chargers for rechargeable tools.
Before using Wagan's inverter, please check the equipment
manufacturer's manual and specification to check if the equipment is
capable of being charged properly without damaging it.
www.wagan.com
3
®
TROUBLESHOOTING
Problem: AC product does not operate, green light does not light
Probable Cause
AC product connected is rated at
more than 150 watts; overload
shutdown occurs.
High starting surge has caused
overload shutdown even though AC
product connected is rated at less
than 450 watts.
Lighter socket or 12 volt outlet may
require ignition to be switched on.
Poor contact with lighter socket or 12
volt outlet.
Battery is discharged.
Fuse blown by heavy load.
Problem: Buzzing sound in audio systems
Inexpensive stereo systems have an inadequate internal power supply filtering
which causes a buzzing sound. A system with a high quality filter is the only
solution.
For additional technical support please e-mail customerservice@wagan.com
User's Manual—Read before using this equipment
Suggested Remedy
Use product with a power rating of
less than 150 watts.
Product exceeds inverter's surge
capability. Use a product with
starting surge power of less than
450 watts.
Turn ignition key to accessory
position.
Press inverter firmly into the lighter
socket. Make sure the socket is
clean.
Recharge battery.
Replace the 20A slow blow fuse by
unscrewing the fitting in the positive
connector.
©2012 Wagan Corporation. All Rights Reserved.
Wagan Tech and wagan.com are trademarks used by Wagan Corporation.