Read the product description before installing the unit. Ensure
that the product is suitable for your application without any
restrictions.
Non-adherence to the operating instructions or technical data
can lead to personal injury and/or damage to property.
In all applications check compliance of the product materials
(see Technical data) with the media to be measured.
Function and features
The pressure sensor detects the system pressure and converts it into
an analogue output signal (4 ... 20 mA). The measuring range can be
scaled (→ page 19, 21).
It is also indicated:
• System pressure above the measuring range: output signal > 20mA.
• System pressure below the measuring range: output signal drops to
max. 3.2 mA (depending on the scaling).
Applications (Type of pressure: relative pressure):
Measuring range
bar
-0.99 ... 4.00
PSI
-14.4 ... 58.0
kPa
Avoid static and dynamic overpressure exceeding the given over-
load pressure.
Even if the bursting pressure is exceeded only for a short time
the unit can be destroyed (danger of injuries)!
The unit is ready for operation when delivered.
Factory preset: ASP = 0.00 bar; AEP = 4.00 bar.
All manuals and user guides at all-guides.com
Safety instructions
-99 ... 400
Permissible
overl. pressure
30
435
3 000
1
Bursting
pressure
100
1 450
10 000
13