Water Pipe Installation
The icemaker must be connected to the cold water supply
line. You will need a 1/4" (OD) copper tubing or 1/4" (OD) plastic
tubing for the water supply line. Additionally, a 1/4" water shut
off vale can be placed near the refrigerator. The shut off valve
shall be easily accessible, so that it can be activated during
winterization or the icemaker is not being used.
Connector Type
Verify the connector type and follow the instructions to finish
the water pipe connection.
Connector A
Connector A
1.
In the lower right corner of the back of the refrigerator as
shown in the picture, remove the rubber cap on the inlet
water interface.
2. Take the water valve connector from the accessory
bag. Remove the blue clip from the connector, place the
connector to the water inlet and turn clockwise to make
it tight.
3. Take out the soft pipe from the freezer drawer, insert it
into the quick water valve connector and push it to the
end, the soft pipe should be 1/4 inch (6.35mm) in external
diameter
CCD-0006076 Rev: 01-10-23
Connector B
pipe
d=¼"
- 7 -
4. Put the blue clip back to the valve connector to lock the
connection.
5. Open the water shut off valve of the vehicle. Examine the
connections for leaks.
6. If testing for water leaks with compressed air, do not
exceed 100PSI of pressure.
Connector B
1.
Remove the blue clip from the connector.
2. Take out the soft pipe from the freezer drawer, insert it
into the connector and push it to the end, the soft pipe
should be 1/4 inch (6.35mm) in external diameter.
3. Put the blue clip back to the connector to lock the
connection.
4. Open the water shut off valve of the vehicle. Examine the
connections for leaks.
5. If testing for water leaks with compressed air, do not
exceed 100PSI of pressure.
pipe
d=¼"