MAINTENANCE - Easi-Access™
The Titan laminator can be opened manually by selecting the 'open' setting (
Please note: the power supply and the machine must both be ON to release the electronic safety catch.
Select the 'open' setting
(
) using the naviga-
tion buttons on the
control panel. Press 'OK'
button.
Lift the top cover with
both hands. You will
see the laminating
engine and belt-drive
mechanism.
ADJUSTABLE ENTRY GUIDE
INTEGRATED CARRY POINTS
404415_2_EUR_Titan_All_v3.0.indd 7
All manuals and user guides at all-guides.com
The ready LED will
flash and the machine
will cool down. This
may take between
30-60 minutes.
To open the belt-drive
mechanism, Pull the 2 cam
levers forwards, on each
side of the mechanism. The
upper carriage can now
be lifted upwards from the
front. Lift the carriage and
open fully until it stops in
the rest position.
The Entry Guide can be manually adjusted (especially for smaller documents) to ensure the
items are best supported when inserted and helps avoid mis-feeds.
The Titan laminator has integrated carry points for safe and easy movement of the laminator
– push in the flaps on both ends of the laminator to get to them.
) on the control panel.
When the machine has
To open the top cover,
cooled to a safe tempera-
move the levers on each
ture, the ready LED will
side of the machine
stop flashing and an alert
backwards to release the
will sound.
electronic safety catch.
Take care when cleaning
IMPORTANT:
any residue from the roll-
When closing the mecha-
ers. Fellowes laminator
nism, ensure the 2 cam
wipes (CRC# 57037) are
levers are both pushed
recommended.
forwards to lock the belt-
drive carriage correctly in
position. The lid can be
closed when the carriage
is correctly locked.
7