6942
The instruction manual is downloadable from the site www.vimar.
com
Technical characteristics
Additional power supply for intallation with more than 50 digital distributors
(type 949B) or 280 internal code type interphones (monitors).
Used only for line supplying the interphones (monitors) or for switchboard
supply ; housed in a grey thermoplastic case.
Designed for mounting on equipment panels with DIN omega rails (12 mo-
dles), or wall fixing with masonry plugs.
Main power supplier data:
-
Dimensions: 208x135x72
-
Power supplier weight:: 1,5Kg
-
Power supply: 230V A.C. (+6/-10%) 50-60Hz (other power supplies are
available on request)
-
Maximum absorbed power: 70VA
-
Low voltage supply: 13,5VDC 1,5A continuous cycle (maximum of 50 dis-
tributors Art. 949B and one entrance panel, or 200 appliances type Art.
6204, 887B or 887B/1 and one entrance panel).
-
Lock output: 15V rectified 1A intermittent cycle (30 sec. ON, 480 sec.
OFF)
-
Outputs for activation of additional functions: 12VDC 0,15A intermittent
cycle 255 sec. ON, 255 sec. OFF (maximum of 1 relay type 170/001, etc.).
-
Class II symbol
Built-in protection features:
-
Transformer primary: PTC tipo SIEMENS C840
-
1st secondary, driving internal electronic circuits: Fusibile F 3,15AL 250V
(F1)
-
Secondary transformer winding supplying door lock and/or lamps: Fusibile
F 3,15AL 250V (F1)
-
Generator of electronic call
-
Electronic interphone riser or panel short-circuit or overload cutout
LED status indicator unit:
L1 - Lock power supply (15 and S1 terminals)
L2 - Door lock command (terminal S)
L3 - Auxiliary function 1 (terminal F1)
L4 - Auxiliary function 2 (terminal F2)
L6 - Digital circuit power supply (terminals 4 and 5)
Description of power supplier terminal functions:
CH
Not used
S
Door lock release control line.
This terminal is used by the entrance panels or switchboard to release
the door lock for the corresponding entrance panel or switchboard.
When terminal S is shorted to terminal 4, terminal S1 is shorted to
terminal 0 (15V rectified) and LEDS L1 and L2 illuminates. Terminal
S1 remains shorted for the time terminal S is activated.
F1
Auxiliary function 1 activation control line.
This terminal is used by the entrance panels or switchboard to activate
function F1. When terminal F1 is shorted to terminal 4, the voltage at
terminal R1 increases to 12 Vdc and remains at this voltage for the
time terminal F1 is shorted. Activation of the function is signalled by
illumination of LED L3.
F2
Auxiliary function 2 activation control line.
This terminal is used by the entrance panels or switchboard to activate
function F2. When terminal F2 is shorted to terminal 4, the voltage at
terminal R2 increases to 12 Vdc and remains at this voltage for the
time terminal F2 is shorted. Activation of the function is signalled by
illumination of LED L4.
3
Not used
4
Digital circuit power line (negative).
5
Digital circuit power line (+ 13.5 Vdc 1.5A).
Energisation of terminal 5 is indicated by illumination of LED L6.
4
Auxiliary function power line (negative).
R1
Auxiliary function 1 power line (+ 12 Vdc 0.15 A).
This terminal activates a relay when function F1 is activated. When ter-
minal F1 is activated, terminal R1 is powered by a 12 Vdc voltage.
4
Auxiliary function power line (negative).
R2
Auxiliary function 2 power line (+ 12 Vdc 0.15 A).
This terminal activates a relay when function F2 is activated. When ter-
minal F2 is activated, terminal R2 is powered by a 12 Vdc voltage.
S1
Door lock release line (1A).
When terminal S is activated, terminal S1 is shorted to terminal 0 and
LEDS L1 and L2 illuminates. The line is protected by a fuse F 3,15A
All manuals and user guides at all-guides.com
15-0
PRIM Power terminals: 230 Vac +6/-10% 50-60Hz.
Installation
The 6942 power unit must be located in a dry, dustfree place away from heat
sources. The location should afford ease of access for the purposes of in-
spection and setting operations. The unit can be mounted either to the wall,
using the fixing plugs provided, or to an equipment panel with DIN omega rails.
Before any connections are made, checks should be made (using a normal
tester) to ensure that there are no conductors broken or short circuiting. It is
good practice to run system wiring and mains wiring through separate con-
duits. To ensure maximum user safety, all devices operate at low voltage and
are separated from the mains by an isolation transformer of high specification.
It is recommended in any event that a circuit breaker of adequate rated capac-
ity should be wired between the mains supply and the equipment. Thereafter :
1)
2)
3)
YELLOW LED
YELLOW LED
GREEN LED
YELLOW LED
RED LED
Installation rules
Installation should be carried out by qualified personnel in compliance with the
current regulations regarding the installation of electrical equipment in the country
where the products are installed.
Ensure clearance around the appliance so there is sufficient ventilation.
There must be no dripping or splashes of water on the appliance.
WARNING: To prevent injury, the appliance must be secured to the wall as
described in the installation instructions.
Above the power supply there must be a bipolar circuit breaker that is easily
accessible with a contact gap of at least 3 mm.
Conformity
LV directive
EMC directive
Standards EN 60065, EN 61000-6-1, EN 61000-6-3.
Power supplies constitute SELV sources in compliance with the requirements stipulated in Article
411.1.2.2 of CEI standard 64-8 (ed. 2012).
waste center, or return it to the retailer when purchasing a new one. Products for
disposal can be consigned free of charge (without any new purchase obligation) to
retailers with a sales area of at least 400m
efficient sorted waste collection for the environmentally friendly disposal of the used
device, or its subsequent recycling, helps avoid the potential negative effects on
the environment and people's health, and encourages the re-use and/or recycling
of the construction materials.
EN
250V (F2)
15V (rectified) line: 1A door lock release.
These terminals power the name card illumination lamps, door lock and
services.
The line is protected by a fuse F 3,15A 250V (F2)
These terminals are mounted under the thermoplastic protection
marked by the symbol
and are used to power the relay connec-
tions. No earth terminal is fitted, this being a power supplier con-
structed to Class 2 specifications.
Wire up the connection terminals as eclosed diagrams of Art. 6941 and
6948 power supplies.
Wire up the power supply terminals located under the rear shield.
Switch on the unit : following initial acclimatization of the system, LED L6
should remain alight, indicating that power lines to the entrance panel/
doorlock and the user interphones are on
WEEE - Information for users
If the crossed-out bin symbol appears on the equipment or packaging, this
means the product must not be included with other general waste at the
end of its working life. The user must take the worn product to a sorted
, if they measure less than 25cm. An
2
3

Publicité

loading