Adjustments
5
Adjustments
5.1
Adjustment of the gripping range
The gripping range of the device (BSZ-KH) must be adjusted and checked absolutely before
using it.
Although the abrasion on the rubber grippers must be adjusted.
Position the device in the middle or in the centre of gravity of the gripping good and lowering it. The device
closes round the product (automatic release disengages itself) and it can be lifted.
The lifting procedure of the device (BSZ-KH) with the support frame must be implemented so long, until the
gripping good is gripped.
Check with the help of the pointer (on both sides) if the gripping arms are adjusted correct.
Is the pointer (when device is lifted) over the nick, the tension force is adjusted optimal (Fig. 1).
Is the pointer (when device is lifted) outside the nick (marking), readjust the tension force
with the help of the 4 spindles (Figure 2). Danger: gripping good could fall down!
Fig. 1
Fig. 2
53100411
Fig. 2a
Gripping range is set correctly.
(1)
Unload the unit by lowering it
Fold up the safety flaps (1).
(2)
Turn spindles (2) clockwise and set all 4
spindles to the same setting dimension!
Measure the setting dimension of all 4
spindles (Fig. 4).
Then secure the spindles (2) again with the
safety flap (1).