PROBLEM
Flame is obstructed at burner
Appliance emits a
ports
lot of black smoke
when lit
Regulator hose is pinched
Nog as flow
Sudden drop in
Excess flow safety valve has
gas flow
been activated
High or gusting winds
No gas flow
Flame blow out
Excess flow safety valve has
been activated
Irregular flame
pattern or flame
does not come out
Burner ports are clogged
of the entire length
of the burner
26
CAUSE
CORRECTIVE ACTION
Make sure all the gas burner ports
are free of any lava rocks or debris
to allow the gas to flow freely.
Check the regulator hose for bends
or kinks
Check if gas cylinder is empty. If
yes, replace.
Turn the control knob to"OFF",
Close the LP tank valve and
disconnect the regulator from the
tank. Turn the control knob to
"HIGH". Wait for 1 minute.Turner
the control knob to "OFF".
Reconnect regulator top tank. Open
tank valve slowly. Light appliance
as indicated in "To Light" section.
Increase flame to"High"
Check if gas cylinder ise mpty.
If yes, replace
See"Sudden dropingas flow" above
See "Burner will not light using a
match" above.
FR
MANUEL DU PROPRIÉTAIRE
Guide de l'utilisateur de la table de foyer extérieur carrée
TABLE DE FOYER 28"x 28"
CONSERVEZ CES INSTRUCTIONS
Le produit a été testé et certifié CSA
27