2. Repeat step 1 with the other end of the lamp.
DETAILED SPECIFICATIONS
Test voltage
(with new battery)
Field strength
Maximum antenna
length
Filament test
Non-contact voltage
detection
Non-contact voltage
sensitivity (with probe)
Drop proof
Operating time
Operating temperature -10
Storage temperature
Operating altitude
All manuals and user guides at all-guides.com
Figure 10: Plug
the lamp into the
pin test slots
Approximately 3 kV / 280 kHz
Approximately 100 μV/m at 260 - 300 kHz
121.92cm (48")
T2, T4, T5, T8, T9, T10, T12
AC 90 V to AC 600 V, 50/60 Hz
CAT III 300 V, CAT II 600 V
LED illuminates and beeps at approximately 3 mm
(0.12 in) distance from a wire carrying 120 Vac
LED illuminates and beeps at approximately 5 mm
(0.2 in) distance from a wire carrying 230 Vac
1 meter
One second ON, one second OFF for maximum
five cycles and wait for 1 minute before making
another measurement
C to +50
O
-10
C to +50
O
Up to 2000 meters
Figure 11: Pin test indications
C (14
F to 122
F) ≤85% RH
O
O
O
C (14
F to 122
F) ≤85% RH
O
O
O
14
LED indicator ON
Solid continuous beep

Publicité

loading

Ce manuel est également adapté pour:

Lt-10-eur