Télécharger Imprimer la page

ESAB LHF 400 Manuel D'instructions page 29

Masquer les pouces Voir aussi pour LHF 400:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 40
GB
3
INTRODUCTION
LHF 400/630/800 are thyristor controlled welding rectifiers designed for welding with
coated electrodes, TIG welding and arc air gouging.
The welding rectifiers can be used with the following remote control devices:
PHA 1, PHA 2, PHA 5, PHB 1, PHB 2, och PHC 2.
An auxiliary control unit is required for TIG welding with high frequency arc ignition.
LHF 400/630, versions with meters and timed cooling fan.
These welding rectifiers are equipped with a volmeter, ammeter and a circuit that
reduces the idle speed of the cooling fan.
The meters allow current and voltage settings to be read from the front of the
rectifier.
To minimise the amount of dust and dirt that is drawn into the rectifier the fan runs at
a reduced idle speed of 300 rpm. When welding with currents greater than 30 A the
fan speed increases to its working speed of around 1350 rpm. A timer relay
maintains the higher speed setting for 6 1/2 minutes after welding has stopped to
ensure adequate cooling of the rectifier.
4
TECHNICAL DATA
Maximum load
35 % duty cycle
60 % duty cycle
100 % duty cycle
Setting range
Open circuit volt.
Open circuit output
at 400 V
Power factor
(max current)
Efficiency
(max current)
Enclosure class
Application class
Weight
Dimens. lxwxh
Duty cycle
The duty cycle refers to the time as a percentage of a ten–minute period that you can weld at a cer-
tain load without overloading.
Enclosure class
The IP code indicates the enclosure class, i. e. the degree of protection against penetration by solid
objects or water. Equipment marked IP23 is designed for indoor and outdoor use.
Application class
The symbol
indicates that the power source is designed for use in areas with increased
electrical hazard.
bh10d13e
All manuals and user guides at all-guides.com
LHF 400
400 A/36 V
315 A/33 V
250 A/30 V
8A/20V–400A/36V
80–87 V
340 W
0,90
74 %
IP 23
195 kg
1310/765/705
– 29 –
LHF 630
LHF 800
630 A/44 V
800 A/44 V
500 A/40 V
630 A/44 V
400 A/36 V
500 A/40 V
8A/20V–630A/44(49)
8A/20V–800A/44(50)
V
V
65–72 V
65–72 V
615 W
640 W
0,87
0,82
77 %
78 %
IP 23
IP 23
260 kg
295 kg
1310/765/705
1310/765/705

Publicité

loading

Ce manuel est également adapté pour:

Lhf 630Lhf 800