The floor sensor has the following temperature / resistance
values:
15°C / 15,8 kΩ
20°C / 12,5 kΩ
25°C / 10,0 kΩ
30°C / 8,04 kΩ
35°C / 6,51 kΩ
The floor sensor may be replaced by a new one. In the event
of malfunction of the room sensor the entire thermostat
must be replaced.
5.3 Calibration of temperature
If the desired temperature is not reached or if there is a
difference between real floor/room temperature and the set
value on the display, calibrate the thermostat.
Push OK continuously for full 6 seconds to enter following
Menu:
• Menu 1:
<
>
• Menu 2:
<
>
temperature
Menu 1:
Service read-out of actual measured temperature (only
valid in floor sensing mode) <
To check the actual measured temperature, push the
This value can be used to calibrate the floor surface
temperature value to the set temperature value on the
display. Push confirmation button several times (scroll
through Menu structure) for leaving the Configuration mode
to Normal mode
<
read-out actual measured temperature
calibration of the floor/room
>:
confirmation button for 6 sec.
In menu number 1 the
measured temperature value is
indicated on the display: in-
floor temperature in case of
floor sensing mode <
>
>.