5 | Connection
On the luminaire is an input for about a M12 connector S-type encoded. About this jack and with suitable connection
material the luminaire is connected with a 220–240V AC electric power supply system.
Suitable connection material, cables and accessories can be found in the accessory range of LED2WORK.
PIN assignment of the M12 connector is as follows:
PIN assignment
PIN 1
= not connected
PIN 2
= external conductor/phase (L)
PIN 3
= neutral conductor (N)
PIN 4
= protective earth conductor (PE)
6 | Maintenance and Care
The LED luminaire is maintenance-free. Do not make any alterations to the luminaire (except according to the mounting
information contained in this manual).
The LED light sources mounted in the luminaire are connected to the luminaire housing in a special way (thermal
coupling) and may react sensitively to electrostatic discharges (ESD). Improper replacement of the illuminant or other
components may impair the tightness of the luminaire. That is the reason why repairs may only be carried out by the
manufacturer or by persons authorised and qualified by the manufacturer.
Turn off the light before cleaning and let it cool down completely. Clean the outside of the luminaire with a soft, dry and
clean cloth. To remove excess dirt, moisten the cloth with water. Never use aggressive cleaning agents, as these may
cause discolouration of the housing.
10 | BA TUBELED_70 AC . BA 11/2022
Schematic drawing of M12 S-type encoded
For the installation on the power supply system the luminaire must be electrically load-
free. This means that if the luminaire is connected directly to a machine or a 220–240V
AC power supply, these must be switched off and load-free for installation, otherwise
the LEDs may be destroyed.
Do not open the luminaire!
No liability is assumed for damages resulting from the use of unsuitable cleaning agents.
brown
black
blue
green/yellow