Télécharger Imprimer la page

Napoleon CLEARion Elite Manuel D'installation Et D'opération page 16

Pour l'utilisation intérieur seulement
Masquer les pouces Voir aussi pour CLEARion Elite:

Publicité

Les langues disponibles

Les langues disponibles

electrical information
EN
3.3 hard-wire connection
Remove the cover plate by remove the 3 screws. Set
A.
screws aside.
Add a strain relief and feed the supply wires through
B.
the 7/8" (22mm) hole from the terminal block. Use
minimum 14AWG/3.
Loosen the securing screws from the terminal block
C.
for the Yellow & Green (G) wire. Insert Yellow & Green
(G) or bare copper wire from power supply to the
designated (G) slots in the terminal block. Secure by
tightening the screws on the (G) slots.
Loosen the securing screws from the terminal block
D.
for the Blue (N) wire. Insert Blue (N) wire from power
supply to the designated (N) slots in the terminal
block. Secure by tightening the screws on the (N)
slots.
Loosen the securing screws from the terminal block
E.
for the Black (L) wire. Insert Black (L) wire from power
supply to the designated (L) slots in the terminal
block. Secure by tightening the screws on the (L) slots.
Reinstall the cover plate.
F.
note:
Leave enough wiring so that the appliance can be removed from the enclosure to access the hardwire
connections.
If connections are wired incorrectly, the appliance will not function and will emit an audible warning (i.e. beep).