Télécharger Imprimer la page

IFM Electronic Efector 200 OL Serie Notice Pour Utilisateurs page 7

Publicité

Les langues disponibles

Les langues disponibles

All manuals and user guides at all-guides.com
Function and features
In conjunction with a prismatic reflector or reflective tape the retro-
reflective sensor detects objects and materials without contact and
indicates their presence by a switched signal.
Range (r): see type label (value referred to prismatic reflector with
∅ 80mm).
Electrical connection
Isolate power, then connect the unit (see page 17 or type label).
Core colours: BN = brown, BU = blue, BK = black, WH = white.
Programming of the output function by push button (see page 11).
The units with cable gland have a removable terminal block with screw
terminals (screws are at the base of the terminal block).
After connection of the wires the terminal block must be reinserted.
Note: insert a miniature fuse according to the technical data sheet, if specified.
Recommendation: check the unit for reliable function after a short cirucit.
Installation
push button
LEDs red
yellow
green
yellow LED
Fix prismatic reflector / reflective tape in desired position. Align the
photocell photocell towards the reflector and fasten it to a mounting
bracket; the light spot must hit the prismatic reflector.
Maximum range is only possible with precise alignment.
7

Publicité

loading