During the measurement (about 1s) allow at least two objects to
move through the detection area.
2
The yellow and green LEDs go out for approx. 1s,
then flash again alternately.
During the measurement (about 1s) allow at least two objects to
move through the detection area.
3
The yellow and green LEDs go out for approx. 1s,
after approx. 3s the green LED is on.
The unit is in the operating mode.
If the setting of the sensitivity is not possible (e.g. object signal
and background signal are about the same), the red LED flashes
after step 3 for approx. 2s. The unit then passes into the operat-
ing mode with the sensitivity being unchanged.
If the setting button is not activated for 15 minutes during the
programming process, the unit passes automatically into the
operating mode with the sensitivity being unchanged.
Setting of the maximum sensitivity
• Go into the programming mode (step 1).
• Align the unit so that no light is reflected.
• Press the setting button twice (see steps 2 and 3).
10
All manuals and user guides at all-guides.com
Press once.
Press once.