INSTALLATION INSTRUCTIONS
PREPARING THE ENCLOSURE
Gloves and safety goggles should be worn during
installation.
It is not recommended to install the appliance into
a corner or directly beside a wall. The door will
need to be opened more than 90° to allow for the
removal of the ice bucket. If it is necessary to place
the unit next to a wall or in a corner, leave at least
2-4 inches (5-10 cm) of space between the wall and
the appliance to allow for the door opening.
The cabinet opening must be at least 15 inches (38
cm) wide by 35 inches (88.9 cm) high by 25 inches
(63.5 cm) deep.
Note: The listed depth requirement is assuming that
the electrical outlet and the water supply are located
in the adjacent cabinetry or fl ush mounted in the
rear wall, not surface mounted inside the enclosure.
If the electrical outlet and water supply are located
inside adjacent cabinetry, cut a 1.5 inch (3.8 cm)
diameter hole to admit the power cord and water
inlet hose. If the cabinet wall is metal, the hole edge
must be covered with a bushing or grommet.
1.5 in (3.8 cm) diameter
35 in
*If electrical outlet in
(88.9 cm)
adjacent cabinetry
Electrical and Water Access
Electrical and Water Access
25 in
(63.5 cm)
15 in (38 cm)
REQUIRED TOOLS
• Safety goggles
• Gloves
• Tape measure
• Carpenter square
• Level
• Flashlight
• Electric drill with hole bit
Safety goggles
Electric drill with hole bit
Gloves
2 in (5 cm)
6 in
(15.2 cm)
90°
4
Tape measure
Carpenter square
Flashlight
Level