INSTALLATION INSTRUCTIONS
Step 2. Prepare Mounting Surface
Please identify the appropriate hardware for the
mounting surface.
For Standard Installation
Remove the bed and chassis from the box
and select the wall area where the unit will
be installed. Make sure you have taken
into consideration the operating clearance
of 24.1 cm on both sides of the exposed
chassis and 58.9 cm from wall surface
when open. Measure from the fl oor 107
cm on stud center and mark the wall. The
mounting holes are designed for 40.6 cm
stud centers. Ensure the locations you
have marked for the mounting holes are
level before drilling. Drill pilot holes for
keyhole mounting using a 3 mm regular
drill bit.
For Masonry or Tile over Stud Wall
Use a 5 mm masonry drill bit for the pilot
hole until you hit the stud. Change bit to 3
mm regular drill bit.
For Metal Stud or Concrete Block
If the wall has metal studs or an
underlying surface of concrete block, you
will need to use toggles. Additionally, if
the wall has wooden studs that are not
on 40.6 cm centers, you will need to use
toggles to secure one side of the unit. The
other side should be secured to the stud
using the screws provided. You must allow
for space inside the wall for the toggles
to turn. This will vary depending on the
toggles used.
3
24,1 cm
58,9 cm
40,6 cm
Frame is equipped
with keyhole slots
to assist with
mounting.
Top two screws at 107
24,1 cm
cm (42¼") to meet
ADA Height
Requirements