Pentair MYERS ME40MC-11-CI Notice D'utilisation page 7

Pompes de puisard submersibles pour matières solides
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Troubleshooting
Risk of electrical shock, cuts, and possible unexpected starts. If the power is on to the pump when
thermal overload resets, the pump may start without warning. If you are working on the pump, you may get an
electrical shock or the impeller may catch fingers or tools. Disconnect the power before servicing the pump.
Symptom
Possible Cause(s) / Corrective Action
1. C heck to be sure that power cord is securely plugged into outlet or securely wired into controller or switch box. Disconnect
2. Check to be sure you have electrical power.
3. Check that liquid fluid level is high enough to activate switch or controller.
Pump fails to operate.
4. Check to be sure that 3/16" (5mm) vent hole in discharge pipe is not plugged.
5. Check for blockage in pump inlet, impeller, check valve or discharge pipe.
6. Disconnect the pump from the power source for a minimum of 30 minutes to allow the motor to cool and to protect yourself
1. Be sure all valves in discharge pipe are fully open.
2. Clean out discharge pipe and check valve.
Pump fails to empty sump.
3. Check for blockage in pump inlet or impeller.
4. Pump not sized properly. A higher capacity pump may be required.
1. Check switch or controller automatic floats for proper operation and location. See installation instructions for switch/controller.
Pump will not shut off.
2. If pump is completely inoperative or continues to malfunction, consult your local serviceman.
power to outlet before handling pump or motor.
from sudden starts. See Warning above. Check for the cause of overheating. Pump is running dry because the float switch is
caught up on something. Inlet pipe is plugged. Outlet pipe is plugged.
7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Myers me40pc-11-ci

Table des Matières