All manuals and user guides at all-guides.com
4. CONTINUITY AND RESISTANCE
Never test resistance on a live circuit
Select the ohmmeter (Ω Ω Ω Ω Ω
Connect the multimeter to the circuit terminals or the
component to be tested.
Ω /
Ω /
Press the Ω /
Ω /
Ω /
button to go from resistance measurement
to the continuity sound test and vice-versa.
Automatic range selection: read off the value
To store value in memory, press the HOLD button.
As necessary, press the following buttons:
MIN-MAX to read the min. or max. values
to light the display
4.1 Resistance
Ω Ω Ω Ω Ω
400 Ω
4 kΩ
Digital
0.1 Ω
1 Ω
resolution
± 1%
Accuracy
R ± 3 ct
Open
≤ 1.2 V
circuit
...
voltage
Protection
4.2 Continuity sound test
On the 400 Ω range a beep sound is given off for a resistance
R ≤ 35 Ω. Temporal response: 100 ms approx.
5. DIODE TEST
Never carry out a diode test on a live circuit
Select the function
Connect the leads to the multimeter and to the terminals
of the component to be tested.
In the forward bias the voltage at the junction is displayed
(1 mV resolution):
- open circuit voltage: typically 3.5 V
- short circuit current: 1 mA,
- in the reverse bias the open circuit voltage is displayed
(in the order of 4 V),
- with no component connected, OL is displayed.
If desired, store the value by pressing the HOLD button.
) ) ) ) ) function.
40 kΩ 400 kΩ 4 MΩ 40 MΩ
10 Ω
100 Ω
1 kΩ
± 1% R ± 2 ct
≤ 0.45 V ...
500 V RMS and 750 V peak
,
DC
16
10 kΩ
± 2%
R ± 3 ct