HBM Anybus CompactCom Modbus TCP Manuel D'instructions page 3

Publicité

Les langues disponibles

Les langues disponibles

Anybus, Modbus TCP
1
Introduction
The Anybus-CompactCom Modbus TCP Anybus module can be mounted in
DIS2116 and DWS2103 digital indicators. If the DWS2103 digital indicator is
fitted with this module, access to type AED/FIT digital transducer electronics
is also possible.
This documentation contains a list of the parameters available for these
devices for cyclic and acyclic data and their assignment to Modbus TCP
addresses.
There are three ways to set the fieldbus parameters:
• Via the indicator fieldbus menu
You can set the IP addresses, subnet mask, gateway and DHCP
functionality with this menu.
• Via your PLC configuration program
As the procedure differs from PLC to PLC, read the manual for your PLC to
discover how to make the settings.
• Via the Anybus module web interface, see page 4.
Process variables are identified by your ASCII command. For a description of
the commands, refer to "DIS2116 Communication Commands" and
"DWS2103 Communication Commands" in the operating manuals and the
AED/FIT Online Help.
1.1 Meaning of the Anybus module LEDs
1
Network status LED
LED status
Description
Off
No voltage supply or no IP address
Green
Module status is "Process active" or "Idle"
Flashing green
Waiting for connection
Red
Duplicate IP address or serious error
Flashing red
Timeout for "Process active"
An LED test is run after start-up.
A3111−1.0 en/de/fr
1
8
4
3
1 Network status
2
2 Module status
3 Connection/activity
4 Interface
3
HBM