Fault
Insufficient water
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
Spout temperature does not
correspond with temperature set
Temperature regulation not possible
Shower or spout dripping
Instantaneous heater didn't work with
thermostat
English
Cause
- Supply pressure inadequate
- Filters are dirty (96922000)
- Shower filter seal dirty
- Backflow preventers dirty or leaking - Clean backflow preventers,
- Thermostat has not been adjusted
- Hot water temperature too low
- Thermo cartridge calcified
- Dirt or sedimentation on valve seat,
shut-off unit damaged
- Non return valve hasn't moved back - Exchange non return valves
- Flow limiter in handshower isn't
removed
- Filters are dirty
Assembly see page 8
Spare parts (see page 16)
Test certificate (see page 10)
Remedy
- Check water pressure (If a pump
has been installed check to see if
the pump is working).
- Clean filter in front of the mixer
and on the MTC-thermo cartridge
(96922000)
- Clean filter seal between shower
and hose
exchange if necessary
- Adjust thermostat
- Increase hot water temperature to
42 ºC to 65 ºC
- Exchange thermo cartridge
- Clean or exchange shut-off unit
- Remove flow limiter
- Clean the filter / exchange filter
7