Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleaning purposes.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower
system without proper supervision. Persons under
the influence of alcohol or drugs are prohibited from
using this shower system.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The product is not designed to be used with steam
baths!
• The fitting must be installed, flushed and tested after
the valid norms!
Thermostatic mixer in conjunction with
combination boilers
• If fitting a hand shower remove the water limiter from
the shower.
• If the continuous water heater causes any problems,
or you have different water pressures you must
install a water limiter to the cold supply, (ordered
separately,article number 97510000).
6
English
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
anti-pollution function
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Safety Function (see page 11)
The desired maximum temperature for
example max. 42º C can be pre-set thanks
to the safety function.
Adjustment (see page 10)
After the installation, the output temperature
of the thermostat must be checked. A
correction is necessary if the temperature
measured at the output differs from the
temperature set on the thermostat.
Maintenance (see page 15)
To guarantee the smooth running of the
thermostat, it is necessary from time to time
to turn the thermostat from total hot to total
cold.
The mixer is equipped with non return valves.
The non return valves must be checked
regularly according to DIN EN 1717
in accordance with national or regional
regulations (at least once a year).
max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80°C
65°C
max. 70°C / 4 min

Publicité

loading

Ce manuel est également adapté pour:

Sanibel 14642000