3.3
Specifications
Model
Input Rating
Power Input
Connections & Wiring
Standby Power
Output Rating
Power Output
Cold-Load Pickup
Internal Residual
Current Detection
Upstream Breaker
Protection
Output Protection
Electrical Protection
Status Indicators
User Interface &
Control
Buttons/Switches
Operating
Temperature
Environmental
Humidity
Charging Cable Length 12/18/25-ft cable
Ingress Protection
Mounting Type
Mechanical
Dimension (W x H x D)
Net Weight
Certificate
Regulation
Charging Interface
Installation and Operating Instructions | Power Max Level 2 Charging Station | 7 | en
EL-51245-XXXXX EL-51253-XXXXX
208-240 Vac, 16 A
L1, L2, and Ground, hardwired w/ terminal block
< 5 W
208-240 Vac, 16 A
Randomized delay before charge resume after power failure
20 mA CCID per UL 2231
2-pole 20 A
breaker on dedi-
cated circuit,
non-GFCI type
Power output is terminated upon detection of charging connector
plug-out
Over current, short circuit, over voltage, under voltage, ground
fault, surge protection, over temperature
Standby (solid green), charging (flashing green), fault (solid red),
warning (flashing red)
ON/OFF switch, stop button
-22
o
F to +122
o
F (-30
95% relative humidity, non-condensing
Type 3R
Wall-Mount
13.8 x 15.7 x 5.0 inch (350 x 400 x 126 mm), excluding charging
cable and support bracket
15.4 lb (7 kg)
UL, cUL
SAE J1772 compliant charging plug
EL-51254-XXXXX
208-240 Vac, 30 A
208-240 Vac, 30 A, 60 Hz
208-240 Vac, 30 A
208-240 Vac, 30 A
2-pole 40 A breaker on dedicated circuit,
non-GFCI type
o
C to +50
o
C)
18-ft cable
25-ft cable
569217 | REV. D | 09.08.2016