STEP 5: INSTALL THE MOUNTING PLATE
For Wall-Vented
Make the box cutout for the rear wall duct.
– 3 pieces mounting plate:
Use the wall template to determine the location and size of
the box cutout for the rear wall duct.
Attach the exhaust adapter to the rear mounting plate (back
plate) wall side. Push in securely until it is past the top locking
tabs and in the lower locking tabs. Take care to assure the
damper hinge is installed so that it is at the top and that the
damper swings freely.
Carefully guide the exhaust adapter, now attached to the
mounting plate, into the house duct. Before using the screws to
attach the plate to the wall. This will assure proper alignment
for installation.
Return to step 5, item 3 to continue. After completing the
installation of the mounting plate, again check the rear damper
for free movement to assure it will operate properly.
Exhaust Adapter
Slide exhaust
adapter into
guides on
rear panel.
– 15 –
Damper
(hinge side up)
Back Plate
(wall side)
Locking
Tabs
Guides
Figure 30