Télécharger Imprimer la page

EINHELL GC-PW 16 Instructions D'origine page 18

Masquer les pouces Voir aussi pour GC-PW 16:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 21
9. Troubleshooting
Fault
Engine does not
start
Pump fails to prime
Insuffi cient pumping
rate
Important. The pump must not run dry.
The reprinting or reproduction by any other means, in whole or in part, of documentation and papers
accompanying products is permitted only with the express consent of the iSC GmbH.
Subject to technical changes
Anl_GC_PW_16_SPK9.indb 18
Anl_GC_PW_16_SPK9.indb 18
GB
Cause
- Spark plug fouled
- Air fi lter dirty
- No fuel in the tank
- Automatic oil cut-out has not
responded
- Intake valve not in the water
- No water in the pump chamber
- Air in the intake line
- Intake cage (intake valve) blocked
- Max. intake head exceeded
- Intake head too high
- Intake cage soiled
- Water level falling rapidly and intake
line is out of the water-
- Pump performance reduced by de-
posits
- 18 -
Remedy
- Clean or replace the spark plug
- Clean the air fi lter.
- Top up fuel.
- Check oil level, top up engine oil
- Place the intake valve in the water
- Fill the pump chamber with water
through the fi ller neck
- Check the intake line for leaks and
seal it if necessary.
- Clean intake cage
- Check intake head and reduce it if
necessary
- Check intake head and reduce it if
necessary
- Clean intake cage
- Place the intake line at a deeper
level
- Clean pump
24.09.2019 08:45:13
24.09.2019 08:45:13

Publicité

loading

Ce manuel est également adapté pour:

41.905.30