Télécharger Imprimer la page

Broan Elite EW43 Serie Manuel D'installation page 6

Publicité

Les langues disponibles

Les langues disponibles

9. CONNECT WIRING
Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all applicable
codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting
means to prevent power to be switched on accidentally.
Detach the junction box cover from the top of the hood by removing both retaining screws.
Set it aside with its screws.
Remove one knockout from the junction box cover.
Install a UL approved strain relief (not included) on the house power cable at 4" from the
cable end. Run the power cable in the junction box cover opening, then use the strain relief
to secure the house power cable to the junction box cover.
Connect power cable to range hood wiring using included wire connectors. Connect BLACK
to BLACK, WHITE to WHITE and GREEN or BARE WIRE to GREEN ground wire. DO NOT
FORGET TO CONNECT THE GROUND.
Reinstall the junction box cover on top of the hood.
Take care not to pinch wire while reinstalling the junction box cover.
WARNING
!
CAUTION
6
HO0297
HR0226
W
IRE CLAMP
HD1157
W
HITE
G
ROUND
B
LACK
HE0363

Publicité

loading

Ce manuel est également adapté pour:

Ew4336blsEw4330blsEw4330ss