Wiring to Power Supply
CAUTION
: If moving the cooking range is
necessary to install the hood, turn off the
power in an electric range at the main
electrical box. SHUT OFF THE GAS BEFORE
MOVING
A
GAS
ELECTRICAL SHOCK.
THIS RANGE HOOD MUST BE PROPERLY
GROUNDED. MAKE SURE THIS IS DONE BY
QUALIFIED ELECTRICIAN IN ACCORDANCE
WITH
ALL
APPLICABLE
LOCAL
ELECTRICAL
CONNECTING WIRES, SWITCH POWER OFF
AT SERVICE PANEL AND LOCK SERVICE
PANEL TO PREVENT POWER FROM BEING
SWITCHED ON ACCIDENTALLY.
8. If hood is operating normally, connect three
wires (black, white and green) to house wires
and cap with wire connectors.
9. Store wires in the wiring box.
Ductwork Installation
10. Use steel pipe to connect the exhaust on the
hood to the ductwork. Use duct tape to make
all joints secure and air tight.
Duct Cover Installation
11. Mark the position of the Duct Cover-Mounting
Bracket {M}. Use reference E from Table 2
and measurements on page 20-22.
and secure Duct Cover-Mounting Bracket {M}
with two screws (not provided). (Figure 18)
NOTE: Inner duct cover will cover the duct
cover-mounting bracket.
12. Position the entire duct cover up onto the
hood.
13. Secure the inner duct cover with two (3/16" x
3/8") screws {J} to the duct cover-mounting
bracket. Shown in Figure 19.
14. Fasten outer duct cover to Duct Cover Support
{L} with four (4 x 6 mm) screws {J}.
RANGE.
RISK
NATIONAL
AND
CODES.
BEFORE
Attach
Figure 18
OF
Figure 19
13
Attach Together