CONNECTIONS, OPERATING AND DISPLAY ELEMENTS
1
DISPLAY
1
Multi-functional OLED graphics display for information such as preset and audio signal level. It also shows menu items to view
system settings as required.
MENU
2
Combined push-and-turn dial to access the edit menu and select and edit individual menu items.
VENTILATION GRILL
3
In order to avoid overheating of the device, ensure that the ventilation grill is not covered and that air can circulate freely.
4
5
11
POWER SOCKET AND FUSE HOLDER
4
IEC mains socket with built-in fuse holder. A suitable power cable is included.
IMPORTANT: Replace the fuse only with a fuse of the same type. Follow the instructions printed on the housing. In the event of repeated fuse
failure, please contact an authorised service centre.
5
POWER ON / OFF
On / Off switch for power supply to the device.
OUTPUT CH A - CH D (speakON-compatible)
6
SpeakON-compatible loudspeaker outputs for channels A to D. To avoid damage to the equipment, make sure that the total impedance of the
connected speakers is at least 2.7 ohms per channel. The speakON-compatible connectors and the screw connections of each corresponding
channel are wired in parallel.
OUTPUT CH A - CH D (screw connection)
7
Loudspeaker outputs for channels A to D with terminal block connections (screw connectors supplied). To avoid damage to the equipment, make
sure that the total impedance of the connected speakers is at least 2.7 ohms per channel. The speakON-compatible connectors and the screw
connections of each corresponding channel are wired in parallel.
INPUTS 1 - 4 (3-pin XLR)
8
Balanced line inputs for channels 1 to 4 with 3-pin XLR sockets. The XLR sockets and the terminal block connections of each corresponding channel
are wired in parallel.
INPUTS 1 - 4 (terminal block connections)
9
Balanced line inputs for channels 1 to 4 with terminal block connections (connectors supplied). The XLR sockets and the terminal block connections
of each corresponding channel are wired in parallel.
DATA USB
10
USB interface (Type B) for updating device firmware and loudspeaker presets, managing global presets and resetting the lock PIN.
The corresponding Windows PC programme and current update files can be found along with a manual in the download area of the product
at WWW.LD-SYSTEMS.COM
HOUSING FAN
11
In order to avoid overheating of the device, ensure that the fan is not covered and that air can circulate freely.