3.3 Datas
Type
Nominal performance
Heating capacity contin../discontin.m
-under favourable
-less favourable
-not favourable heating circumstances
according to 18893/TAB2 DIN standard
Flue gas values:
Flue gas stream:
Flue gas temperature:
Min. blast pressure at performance:
dust (relating to 13% O²)
CO (relating to 13% O²)
CO
OGC
NOx
efficiency
All information provided by the exhaust gas values are based on the EN 13240 under stationary
laboratory conditions reserve the right to make changes which relate to technical advances and / or
to an improvement in quality. We accept no liability for printing errors and changes which occur
after printing
width
draugh
(mm)
(mm)
A
B
484
484
484
484
536
532
536
532
510
545
510
545
557
497
557
497
3
fuel:
38
height
weight
(mm)
netto:
C
(kg)
1134
115
1183
130
1132
110
1164
142
1134
109
1164
159
1135
112
1165
166
108 30 / 31 / 33 / 34
6 kW
116
69
47
wood / brown coal
9,2 / 7,5 g/s
204 / 237 ˚C
12 Pa
≤ 40 mg/m³
≤ 1250 mg/m³
≤ 1100 mg/MJ
≤ 50 mg/MJ
≤ 150 mg/MJ
≥ 80 %
weight
brutto:
(kg)
133
148
128,5
160,5
127
177
130
184