Clean reminder:
A "CLEAN" reminder will occur every 6 months
to remind you that it may be time to clean your
appliance. Over time mineral build up on the cold
evaporator plate can occur which can adversely
affect the quality of your ice. This build-up is depen-
dent on your water source and usage. Normal ice
production will continue while the "CLEAN" reminder is dis-
played. You may clear the "CLEAN" reminder at any time
by momentarily pressing the "ON/OFF" icon. When reset,
the "CLEAN" reminder will reset and not occur for another
6 months. If you choose to clean the appliance at this time,
see the options menu section below.
Clean mode:
To ensure maximum performance and ice quality, it is
recommended to clean your ice machine once every six
months. This simple cleaning routine will also ensure water
and energy use continues at optimum efficiency.
NOTE
Homes with poor water quality or high clear ice usage
might require more frequent cleaning. This will become
evident from reduced ice quality or quantity.
To clean your ice machine you will need to purchase a
"nickel safe" ice maker cleaner. Cleaner can be obtained by
contacting AGA Marvel customer service at 800-223-3900
or email orderdesk@agamarvel.com.
CAUTION
!
Use only Marvel-approved ice machine cleaner and follow
all label warnings and directions. Incorrect chemical usage,
and any damage that may result, is not covered by war-
ranty.
Available to order
Clear Ice Machine Cleaner, 4-oz. bottle Part # S41013789
CLEANING YOUR ICE MACHINE
Once you have your cleaner:
Turn the ice machine off by pressing and holding the
CLEAN
"ON/OFF" icon for 3 seconds. "OFF" will be dis-
played on the control.
Follow the following three step procedure for
removing the grid cutter cover from the ice machine, Refer
to Figure 25 and Figure 26:
Remove all ice from the ice bin, (see Figure 26).
Drain the water from the water reservoir, by removing the
black plug from the bottom of the fresh water reservoir.
(See Figure 27). After the water is drained replace the plug
in the bottom of the reservoir.
Allow all of the ice to fall from the evaporator plate and
remove any ice from the grid cutter. If there is ice embed-
ded in the grid cutter wires, wait for it to melt and fall out.
Do not try to remove ice that is embedded in the grid
cutter wires as that may break the wires. (See Figure 26
and Figure 27).
Forcing ice through the grid cutter will break the grid cutter
wires.
16
-pull out on this corner first to remove the cover corner
1
from the mounting peg.
-pull out on this corner next to remove it from the
2
mounting peg.
-reach behind cover and push cover towards you to
3
remove cover from the center mounting peg.
CAUTION
!
Figure 23
OFF
Remove all ice
from the evaporator
plate and grid cut-
ter area
Figure 24