man_S20xx.qxd
12-03-2009
Emergency and test operation
Emergency Operation
•
The emergency operation is needed only when the remote control can not be used.
•
When you press the Emergency Operation Switch, you will hear a beep and the emergency operation
starts.
•
Emergency operation is preset for the following two modes, only based on the temperature of the
room at the time of operation.
Temperature
Above 23°C
Below 23°C
NOTE
Emergency operation at the temperature between above 23°C and below 26°C just switch the
machine in operation in "cooling mode" without actually "cooling". It is not possible to operate
in "Dry" mode.
Test operation
•
Same switch as used in Emergency operation.
•
Test operation is needed in special occasion when you need to test the "cooling operation" even with
the room temperature below 16°C, therefore it is not for the normal operation at all.
•
Press the Emergency operation switch and hear the beep once, then keep on pressing the switch for
more than 5 seconds but no more than 10 seconds. After the first 5 seconds you will hear two beeps
then release the switch and you will have the Test Operation Mode.
•
The Test Operation Mode will run the air conditioner at "cooling" with air flow speed at "Hi" for 30
minutes and stops automatically.
Termination of emergency or test operation
•
You can terminate the operation when you hear a beep by either pressing the switch once more, or by
operating through remote control.
•
When you operate through remote control, is automatically get back to just normal operation mode by
remote control.
E
AIR FILTER
This air conditioner is equipped with 3 filter types to clean the circulated room air.
a.
Mold-Proof screen filter; the screen filter removes dust particles from the air. The surface of the screen
filter is mold proof which prevents mold from growing, and thus delivers clean, fresh air from the air-
conditioner.
b.
Photocatalytic Anti-odor Filter; to remove odours.
c.
Static Catechin Filter; Inhibiting proliferation of viruses and germs.
12:32
Pagina 35
Operation
Designated
mode
temperature
Cooling
26°C
Heating
23°C
Timer mode
Air flow
Continuous
Automatic
Continuous
Automatic
4
35