NOTE!
• The air will not flow out unless the heat exchanger gets warm enough in order to prevent cold
air.
• The air conditioner will not start operation for approx. 3 min. in order to protect the
compressor even if you press the ON button right after the operation stops. The operation will
start automatically in 3 min.
• The outdoor unit may frost and heating capacity may deteriorate during the heating
operation. In such case, the unit automatically stops heating operation and conducts
defrosting operation. The fans of the indoor and outdoor units stop during the defrosting
operation.
• We recommend you change the fan speed mode to "Auto" from "High" if you don't feel
warm enough.
• We suggest you use additional heating equipment if it is difficult to warm the room because of
low outdoor temperature.
Automatic operation
In automatic operation the air conditioner selects the operation mode (cooling, dry, heating) according to
the room temperature when it starts.
Room temperature
Heating
Operation
The operation mode, automatically selected when the unit starts, will be reselected after the room tempe-
rature reaches the setting temperature and the outdoor unit stops for 15 minutes or longer.
NOTE
If the selected mode by Automatic operation does not suit you, set the operation mode (cooling,
dry, heating) with the operation mode button.
12:32
Pagina 31
Cooling Operation
Dry
Operation
Outdoor Temperature
1.
Press the ON/OFF button
2.
Set the operation mode to Automatic "AUTO", by pressing the operation
mode button
3.
Adjust the setting temperature by pressing the temperature setting buttons.
4.
Adjust the fan speed by pressing the fan speed button. When the mode is set
at "AUTO" the fan speed changes automatically.
5.
Press the ON/OFF button again.The system will retain the previous setting
conditions until next operation.
• The air conditioner will restart in the previous mode if auto-
matic operation is resumed within 3 hours from the switch-
off.
• Mode review. The computer checks and compares the room
temperature regularly after the compressor shuts off, and
will adapt the operating mode.
4