1. N
1.1 g
enerAl notes on sAfety
This operation manual is applicable for the machine LWB
21.
The machine may only be handled by personnel
who are qualified.
1.2 u
se of the mAchine for PurPoses for
which it is intended
The tool is designed for grinding, milling, and deburring
metal, stone, and plastic with milling cutters and grinding
attachments.
1.3 i
ncorrect use
All uses other than those described under section
1.2 are regarded as incorrect use and are there-
fore not admissible.
1.4 ec
declArAtion of conformity
Translations of the «EG-Koformitätserklärung (Original)».
Suhner Schweiz AG, Industriestrasse 10, CH-5242 Lup-
fig, hereby declares under sole responsibility that the
product with the serial or batch no. (see reverse side)
complies with the requirements under the Directive
2006/42/EG. Applied standards: EN ISO 12100, EN ISO
11148. Document Agent: T. Fischer. CH-Lupfig, 11/2019.
T. Fischer/Managing Division manager
2. C
2.1 P
rior to tAKing the mAchine into serVice
Use oiled compressed air (see also air
quality under section 2.3). Observe nation-
al regulations.
2.2 t
AKing the mAchine into serVice
Before connecting the tool to the com-
pressed air supply set the sleeve to the
«OFF» position! The tool may be switched
on only when the attachment have been installed correct-
ly.
18
S
oTES oN
aFETy
ommISSIoNINg
2.2.1 t
/t
urn on
urn off
Tilt lock forward and press lever on plastic sleeve. Releas-
ing the lever will shut the machine down.
A
lternAtiVe
Switch on the tool by turning in the direction of the arrow
to the stop. Turn back to switch off the tool.
Before cutting off the compressed air supply, al-
ways set the machine to the «OFF» position so
that the tool cannot be reactivated inadvertently.
2.3 r
Ating dAtA
Pressure
Power output
Air consumption full load EN ISO 15744
Air consumption at idling EN ISO 15744
Setting oiler idle
No-load speed
Sound pressure level EN ISO 15744 74dB(A), K=3dB(A)
Vibration EN ISO 28927-12
Air quality DIN ISO 8573-1
Weight
2.4 o
PerAting conditions
Temperature range during operation: 0 to +40°C
Relative air humidity: 95% at +10°C not condensed
max. 6.3bar
250W
0.52m
/min
3
0.6m
/min
3
about 2-3 drops/min
25000min
-1
3.6m/s
, K=2.3m/s
2
2
3/4/4
0.380kg