Télécharger Imprimer la page

RIDGID R350RHE Manuel D'utilisation page 13

Cloueuse de charpentier à tête ronde

Publicité

Les langues disponibles

Les langues disponibles

MAINTENANCE
REQUIRED DAILY CHECKLIST
See Figures 8 and 9, page 16.
 Disconnect the air supply from the tool and remove all
fasteners.
 Check all screws, nuts, bolts, and pins on the tool. If any
of these are loose, they must be tightened with the ap-
propriate size wrench.
 Press the workpiece contact against a workpiece to
ensure that it moves smoothly.
 With the workpiece contact depressed, pull the trigger.
The trigger should move smoothly, without binding.
 Select the single sequential actuation mode ( ).
 While the tool is not loaded, connect the appropriate air
supply (at 70 psi) to the tool.
 Begin inspection:
• Without pulling the trigger, press the workpiece con-
tact against a workpiece several times. The tool must
not actuate.
• With the workpiece contact not engaged on the
workpiece, point the tool down and away and pull the
trigger several times. Hold the trigger in this position
for a minimum of 5 seconds The tool must not actuate.
ACCESSORIES
To order parts and maintenance kits, call 1-866-539-1710.
Driver Maintenance Kit ....................................................................................................................................079005004702
Overhaul Kit .....................................................................................................................................................079005004701
Oil and Wrench Kit...........................................................................................................................................079005004705
WARNING:
Current attachments and accessories available for use with this tool are listed above. Do not use any attachments
or accessories not recommended by the manufacturer of this tool. The use of attachments or accessories not
recommended can result in serious personal injury.
• Load fasteners, then press the workpiece contact
firmly against the workpiece and pull the trigger. The
tool must actuate.
• With the workpiece contact still depressed, release
the trigger. The driver must return to its up position.
 Disconnect the air supply from the tool and remove all
fasteners.
 Select the contact actuation mode (
 Reconnect the tool to the air supply.
 Begin inspection:
• With the workpiece contact not engaged on the
workpiece, point the tool down and away. Pull the trig-
ger. The tool must not actuate.
• Load fasteners, then fully depress the trigger and push
the workpiece contact against a workpiece. The tool
must actuate.
 Disconnect the air supply from the tool and remove all
fasteners.
 If the tool successfully meets all the requirements in this
checklist, it is ready for use. Set the trigger on the tool to
operate in the manner that best fits your application.
 Set the depth of drive according to the Drive Depth
Adjustment section in this manual.
 Connect the tool to the air supply and load the proper
fasteners for the desired application. Repeat this checklist
before using the tool each day, or if the tool is dropped
or damaged in any way.
13 – English
).

Publicité

loading