3.6 Electrical Connection
Although the heat pump is electrically isolated from the rest of the swimming pool
system, this only prevents the flow of electrical current to or from the water in the pool.
Grounding the heat pump is required for protection against short-circuits inside the
unit. Always provide a good grounding connection outlet. If not sure, contact a
qualified electrician for assistance.
Before connecting the unit, verify that the supply voltage matches the operating voltage of the heat
pump.
3.7 Initial Operation
Make sure the pool is fi lled with water to the correct level, the skimmer and suction fi ttings are
below the water level.
To heat the pool water, the fi lter pump must be running to cause the water to circulate through the
heat pump. The heat pump will not start up if the water is not circulating, therefore the heat pump
must operate together with the fi lter pump.
After all the water connections have been attached and checked, carry out the following
procedure:
SET UP INSTRUCTIONS
WARNING
Cable Wiring:
1.Open the wiring block box
(marked white) on the side of
themachine.
2.Fix the other side on joints
inside the electric box follow "L" ,
" N ", "Earth" symbols.
Water Pump W iring :
1.Open the wiring block box
(marked white) on the side of
the machine.
2.Fix the other side on joints
inside the electric box follow "1",
"2" symbols(Max 200W for this
dry contact if it is connected to
water pump directly) .
EN
EN