When replacing an old small water heater with this new appliance, the ex-
isting drill holes with wall plugs can be used. Please note that the new ap-
pliance is approx. 2 cm higher.
• Turn the installation bracket around and attach to the wall with the
notches at the bottom (J).
2.4
Water connection
CAUTION:
Caution!
The existing fitting may not be covered with scaling.
• Do not grease the thread!
Info: Replacement for damaged threaded nozzles available from
customer service.
Undersink appliances TR3500TO 5 T and TR3500TOR 5 T
(Fig. 6)
• Fit the taps if required (A1 and A2).
• Insert the seals (B1).
• Ensure the axial fit of the connection pipes in the nozzles.
• Place the union nuts on the thread and tighten them by hand (B2).
• Tighten the screw fitting (C). Counter the threaded nozzles on the
warm water heater with a wrench
• After the unit has been used to heat water a few times, retighten the
screw fitting.
Oversink appliances TR2500TO 5 B (Fig. 7)
• Install the mixer if required (D1 to D3).
• Insert the pipe connections to the mixer with seals (E). Ensure the
axial fit of the connection pipes in the nozzles.
• Insert the seals on the pipe connection (F1).
• Suspend the appliance (G).
• Place the union nut (F2) on the thread and tighten it by hand.
• Tighten the screw fittings (H1 and H2). Counter the threaded nozzles
on the warm water heater with a wrench (H1).
3
Technical data
Type
Rated output
Rated capacity
CLICKFIX plus installation technology
Pressure stop
Drip stop
Mixed water quantities 40 °C
(15 °C/85 °C) / (15 °C/85 °C)
Variable temperature adjustment up to
Stand-by power consumption at 65 °C/24 h
Electrical connection
Heat-up time to 60 °C
( temperature 12 °C)
Fuse protection
Water connection
Maximum flow
Cable length
Dimensions (Height×Width×Depth)
Weight, filled
Tronic 2500 TO | Tronic 3500 TO | Tronic Store Advanced – 6 720 876 005 (2023/05)
2.5
First start-up
2.5.1
Electrical connection
• Important: Do not insert the plug into the mains socket yet.
• Fill the appliance with water first. Water must flow from the fitting.
• Only then insert the plug into the mains socket.
Note: If the appliance is not filled with water, the resettable safety
temperature limitation will trip!
2.5.2
Checking the heating
• Turn the rotary selector switch to "3" (approx. 85 °C).
• Monitor the heating process until the pilot lamp switches off after
approx. 12–18 minutes.
• Check the temperature.
CAUTION:
If the safety temperature limitation has switched off the small water
heater, unplug the mains plug, open the warm water tap and allow
approx. 4 litres of water to flow. Then plug the mains plug back in.
The appliance is ready again for operation.
2.5.3
Limitation of the water temperature
The temperature of the water leaving the tap for the small water heater
can be mechanically set to stage "1" (approx. 38 °C) or stage "eco"
(approx. 60 °C) (see "Operation", page 13).
Conserving energy
• Set the rotary selector to "eco" to conserve energy.
• Hand over the installation and operating instructions to the user and
explain how the appliance operates.
TR3500TO 5 T
Undersink
[kW]
2.2
[l]
5.0
[l]
9.5/14
[°C]
85
[kWh/d]
0.18
[V]
230
[min]
8
[A]
10
["]
3/8
[l/min]
5
[m]
0.6
[mm]
435×270×240
[kg]
7.7
TR3500TOR 5 T
TR2500TO 5 B
TR3500TO 5 T
Undersink
Over-sink
1.8
2.2
5.0
5.0
–
–
9.5/14
9.5/14
85
85
0.18
0.18
230
230
9
8
10
10
3/8
1/2
5
5
0.6
0.6
435×270×240
435×270×240
7.7
7.7
Subject to change without notice.
Technical data
TR2500TO 5 B
Over-sink
1.8
5.0
–
–
9.5/14
85
0.18
230
9
10
1/2
5
0.6
435×270×240
7.7
11