Burner and nozzle specifications
GB
Table 1
Burner
Fast
(Large) (R)
Reduced Fast
(RR)
Semi Fast
(Medium) (S)
Auxiliary
(Small) (A)
Triple Crown
(TC)
Supply
pressures
*
At 15°C and 1013 mbar-dry gas
**
Propane
***
Butane
Natural
P.C.S. = 37.78 MJ/m
(1) Only for appliances with the security device.
Table 1 (For Hungary)
Burner
Fast (R)
Reduced Fast (RR)
Semi Fast (Medium) (S)
Auxiliary (Small) (A)
Triple Crown (TC)
Supply pressures
At 15°C and 1013 mbar-dry gas
P.C.I. G20
A
R
S
PH 640.../HA
16
Diameter
Thermal Power
(mm)
kW (p.c.s.*)
Nom.
100
3.00
100
2.60
75
1.65
55
1.00
130
3.25
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
P.C.S. = 50.37 MJ/kg.
P.C.S. = 49.47 MJ/kg.
3
By-pass
Thermal
1/100 (mm)
Power kW
3.00
2,90
2.60
2,45
1.65
1,60
1.00
0,90
3.25
3,15
P.C.I. G30
3
35,9 MJ/m
P.C.I. G25.1
A
RR
S
S
PH 640MST.../HA
Liquid Gas
By-pass
1/100
(mm)
Red.
(1)
0.70
41
39
0.70
41
39
0.40
30
28
0.40
30
28
1.50
60
61
G 20
Nozzle
Thermal
1/100 (mm)
Power kW
116
2,25
110
1,90
96
1,25
71
0,65
133
2,45
25 mbar
3
122,8 MJ/m
3
30,9 MJ/m
TC
R
S
PH 631.../HA
Nozzle
Flow*
1/100
g/h
(mm)
***
**
86
218
214
80
189
186
64
120
118
50
73
71
91
236
232
28-30
37
20
25
35
45
G 25.1
Nozzle
Thermal
1/100 (mm)
Power kW
116
2,70
110
2,30
96
1,50
71
0,90
133
2,90
25 mbar
S
Naturale Gas
Nozzle
Flow*
1/100
l/h
(mm)
116
286
110
248
96
157
71
95
133
309
20
17
25
G 30
Nozzle
1/100 (mm)
86
80
64
50
91
30 mbar