Télécharger Imprimer la page

Faber NOVA Instructions D'installation page 4

Publicité

Les langues disponibles

Les langues disponibles

TOOLS NEEDED FOR INSTALLATION
• Saber Saw or Jig Saw
• Drill
• 1 1/4" Wood Drill Bit
• Pliers
• Phillips Screwdriver
• Flat Blade Screwdriver
• Wire Stripper or Utility Knife
• Metal Snips
• Measuring Tape or Ruler
• Level
• Pencil
• Caulking Gun
• Duct Tape
PARTS SUPPLIED FOR INSTALLATION
• 1 Hardware Package
• 1 Literature Package
PARTS NEEDED FOR INSTALLATION
• 2 Conduit Connectors
• Power Supply Cable
• Wiring Cable - Optional Remote Blower Only
• 1 Wall or Roof Cap
• All Metal Ductwork
PLAN THE INSTALLATION
This rangehood can be installed as either ducted or ductless.
The blower can be vented through the wall or ceiling. To
vent through a wall, a 90° elbow is used. When installed
ductless, the rangehood vents out of grates on the sides of
the chimney. Ductless installations require a Ductless Kit,
available from your dealer.
This rangehood can be used with an optional remote blower.
If a remote blower is used, then the internal blower must be
removed and discarded. Both blowers cannot be used together.
The remote blower connects to the rangehood using a separate
wiring cable not supplied with the rangehood. The wiring cable
should be installed at the same time as the ductwork.
WARNING! BEFORE MAKING ANY CUTS OR HOLES
FOR INSTALLATION, DETERMINE WHICH VENTING
METHOD WILL BE USED AND CAREFULLY CALCULATE
ALL MEASUREMENTS.
RANGEHOOD ASSEMBLY
B -
OPTIONAL BACKSPLASH
C -
CANOPY
S
-
UPPER CHIMNEY
LOWER CHIMNEY
I
-
LOWER BRACKET
1
-
2
-
UPPER BRACKET
3
-
MIDDLE CHIMNEY BRACKET
The Nova chimney is adjustable and designed to meet varying
ceiling heights. FIGURE 2 illustrates the standard installa-
tion for the Nova which requires the canopy to be mounted
24" above the countertop. The chimney can be adjusted for
ceilings between 8 feet and 9 feet.
Min. - 1"
Max. - 20"
The ductrun should not exceed 35 feet if ducted with 3 1/4"
by 10" rectangular duct and 60 equivalent feet if ducted with
9" round ductwork. Calculate the length of the ductwork by
adding the equivalent feet in FIGURE 3 for each piece of duct
in the system An example is given in FIGURE 4. For best
results, use no more than three 90° elbows. Make sure that
there is a minimum of 24" of straight duct between elbows if
more than one is used. Do not install two elbows together.
Remote blowers require 9" round duct.
45˚ Elbow
90˚ Elbow
90˚ Flat Elbow
Wall Cap
FIGURE 1
INSTALLATION DIMENSIONS
upper
chimney
cover
lower
22"
chimney
cover
canopy
9 1/2"
19 1/4"
24"
36"
FIGURE 2
CALCULATE THE DUCTRUN LENGTH
7.0 feet
9 Feet Straight Duct
5.0 feet
2 - 90˚ Elbows
12.0 feet
Wall Cap
0.0 feet
Total System
FIGURE 3
WARNING
!
PERSONAL INJURY HAZARD
Because of the weight and size of the rangehood
canopy, two or more people are needed to move
and safely install the rangehood canopy.
Failure to properly lift rangehood could result in
damage to the product or personal injury.
Min. 92 1/2"
Max. 111 1/2"
cabinet
base
9.0 feet
10.0 feet
0.0 feet
19.0 feet
FIGURE 4
Version 11/00 - Page 4

Publicité

loading