Troubleshooting
Possible Problem
After installation, the unit
doesn't work.
Light works, but blower is
not turning.
The unit is vibrating.
The blower is working,
but the lights are not.
The hood is not venting
out properly.
LumiLight LEDs flicker
when changing speed
levels.
28
Possible Cause
The power source is not turned ON.
The power line and the cable locking
connector is not connecting properly.
The switch board wirings are
disconnected.
The switch board is defective.
The blower cable is disconnected.
Debris or obstruction in motor.
Motor defective or possibly seized.
Damaged capacitor.
The switch board is defective.
The blower is not secured in place.
Damaged blower wheel.
The hood is not secured in place.
The LED light connector is
disconnected.
Defective LED light.
The switch board is defective.
Using the wrong size of ducting.
Using the wrong type of ducting.
Flexible ducting can reduce air flow by
up to 50%.
The hood might be hanging to high
from the cook top.
The wind from the opened windows or
opened doors in the surrounding area
are affecting the ventilation of the
hood.
Blockage in the duct opening or
ductwork.
N/A
Breeze I & Breeze II Use, Care, and Installation Guide
Solutions
Make sure the circuit breaker and the unit's
power is ON.
Check the power connection with the unit is
connected properly.
Make sure the wirings at the switch board are
connected properly.
Change the switch board.
Connect the blower cable.
Remove the debris or obstruction.
Change the blower.
Change the capacitor.
Change defective part.
Tighten the blower in place.
Replace the blower.
Check the installation of the hood.
Connect the LED light connector.
Change the LED light.
Change the switch board.
Change the ducting to at least
higher or 7" round or higher (AK12 only).
Change the ducting to solid rigid metal
ducting.
Adjust the distance between the cooktop
and the bottom of the hood within 24" to 36"
for gas cooktops and 20" to 36" for electric
cooktops.
Close all the windows and doors to eliminate
the outside wind flow.
Remove all the blocking from the duct work or
duct opening.
This is a normal operation and the hood is
working correctly.
C O R E
B R E E Z E I &
B R E E Z E I I
U N D E R - C A B I N E T
3-1/4"x10"
or