- The stainless steel housing of the device is not suitable for salt water baths with a high salt content. If the salt content is too high, the steel
will oxidise and damage the housing. Always install the device immediately behind the filter.
- This product can only be used according to the guidelines described in these instructions for use.
Installation of the earth (Drawing 1)
1 Pull the cable (B) through the strain relief (F) before fitting the synthetic strain relief (F) onto the earth bolt (A). Position the strain relief (F)
at approximately 10 cm from the eye (H) of the earth cable (B).
2 Place the eye (H) of the cable (B) onto the earth bolt (A) that is fitted to the housing.
3 Then place a toothed lock washer (C), a hexagon nut (D) and another toothed lock washer (E) on top of the eye (H).
4 Fit the strain relief (F) on top, creating a loop of Ø 5 cm.
5 Finally place the lock nut (G) onto the earth bolt (A).
6 Once the various nuts have been placed onto the earth bolt (A) in the correct sequence, they can be tightened with a spanner or a ring spanner
number 8. Do not tighten too firmly, otherwise you may crack the strain relief. (The transparent nut that was screwed on the earth bolt (A)
on delivery has no further use, and can be discarded).
Installation of the device (Drawing 2+4)
Determine where the device will be installed. The Blue Lagoon UV-C Pro Buster must never be installed behind the Ph regulator or the salt
electrolysis system in your swimming pool installation. The ideal location to install your device is immediately behind the filter. The installation
must always take place outside of the pool. Ensure that there is always water flowing through the unit when the lamp is on. Never install the
unit in an area exposed to full sunlight. The installation must always take place in a dry and well-ventilated area. The device must always be
fitted in the vertical position, and a space of 30 cm must be available underneath to carry out maintenance. An area of approx. 1.5 m must be
available at the top in order to be able to replace the lamp (K) smoothly without having to dismantle the complete device.
1 Determine where the device will be installed. Make sure to leave a free area (+/- 1 metre) in order to be able to remove the lamp (K) / quartz
glass (M) for the purpose of replacement and/or maintenance.
2 Install the UV-C unit in a fixed position; if necessary secure the unit onto a solid rear wall using pipe clips (not supplied).
3 Mount the unit into the circuit. Note: The diameter of the input and output is 3". The diameter of the flow switch is 63 mm. See diagram 4 for
the different connection options. The glue socket for the flow switch (I) must be glued with the screw thread (Z) pointing upwards (see
Drawing 2). Fit the flow switch (X), which is attached to the electronic ballast (Y), perpendicular to the screw thread (Z) of the glue socket
(I) (see Drawing 2). The device will not work if the flow switch is mounted differently. The arrow on top of the flow switch (X) must always
point in the direction in which the water is flowing. The Blue Lagoon UV-C Pro Buster will not switch on if the flow switch is pointing in the
opposite direction (against the flow of the water).
4 Unscrew the screw ring (N) of the lamp on top of the housing (U). Carefully place the quartz glass (M) in the housing (U). Place the o-ring (T)
in the correct position with regard to the quartz glass.
5 Remove the UV-C lamp (K) from the supplied case (see packaging) and carefully slide the lamp into the quartz glass (M). Carefully connect
the white lamp holder (L) to the UV-C lamp (K) and then screw the screw ring (N) hand-tight onto the housing (U). In doing this, pay attention
to the correct position of the O-ring (T) with regard to the quartz glass.
6 Activate the pump and check the flow and any leakage of the system.
7 Put the plug of the UV-C device in a wall socket with a safety ground and fitted with a residual current circuit-breaker. Check whether the
lamp is operating by looking through the transparent components of the unit. The unit is switched off by pulling the plug out of the socket.
Instructions for use of the digital time meter
As soon as the Blue Lagoon UV-C Pro Buster is switched on, the program will carry out a self-test. The display will automatically show the
following , one after the other: 8888 (display test) ; r and software version number ; 50H or 60H indication of the mains frequency
Following this, the display will show the meter reading.
When the UV-C lamp is switched on for the first time, or after the "reset" function has been used, the value '4500' will appear on the display. A
dot next to the digit on the far right of the display will blink every second; this indicates that the counter is running.
The display is automatically set to the factory reading of 4,500 hours. The UV-C lamp operates at 100% radiation for up to 4,500 hours. After
4,500 hours, the radiation will weaken, and may become insufficient to obtain the desired results.
5