Emergency and Test Operation
Emergency operation:
Use this operation only when the remote controller is defective or lost.
When the emergency operation switch is pressed,the" Pi "sound is heard
once, which means the start of this operation.
In this operation, the system automatically selects the operation modes, coo-
ling or heating, according to the room temperature.
When machine is running in emergency, the set value of temperature and wind
speed couldn't be altered; meanwhile, it can't operate for dehumidifying or
under timing mode.
Test operation:
Test operation switch is the same as emergency switch.
Use this switch in the test operation when the room temperature is below
16ºC, do not use it in the normal operation.
Continue to press the test operation switch for more than 5 seconds. After you
hear the "Pi" sound twice, release your finger from the switch: the cooling ope-
ration starts with the air flow speed "Hi".
Removal of the restriction of emergency or test operation
Press the emergency operation switch once more, or manipulate through the remote controller; the "Pi" sound, the emer-
gency or test operation is terminated.
When the remote controller is manipulated, it gets the system back to the normal operation mode.