10 Technical data
10.1 VERSO
10.1.1 General
Made of strong technopolymer (polycarbonate)
Sunshield in ABS
RAL9002 Colour
Stainless steel external screws
10.1.2 Mechanical
Internal usable dimensions (WxH): 70x70mm
(2.7x2.7in)
Internal usable length (with or without accessories):
270mm (10.6in)
Cable glands: 3xM16
Polycarbonate window (WxH): 105x64mm (4.1x2.5in)
Unit weight: 1.5kg (3.3lb)
10.1.3 Electrical
Supply voltage/Current consumption (empty
version):
• From 12Vdc up to 24Vdc, 1A max
• From 12Vac up to 24Vac, 1A max, 50/60Hz
• From 120Vac up to 230Vac, 400mA max, 50/60Hz
Supply voltage/Current consumption (version with
heater, Ton 15°C±3°C (59°F ±5°F), Toff 22°C±3°C
(72°F±5°F)):
• From 12Vdc up to 24Vdc, 5A max
• From 12Vac up to 24Vac, 5A max, 50/60Hz
• From 120Vac up to 230Vac, 700mA max, 50/60Hz
Supply voltage/Current consumption (version with
heater fan assistant, continuous duty):
• 12Vdc, 400mA max
• 24Vac, 200mA max, 50/60Hz
• From 100Vac up to 240Vac, 40mA max,
50/60Hz (with wide-range power supply)
MNVCHPVB_2222_EN
Supply voltage/Current consumption (version with
blower and thermostat for models with double
filter for air renewal, Ton 35°C±3°C (95°F±5°F), Toff
20°C±3°C (71°F±5°F)):
• 12Vdc, 400mA max
• 24Vac, 200mA max, 50/60Hz
Camera power supply:
• IN from 100Vac up to 240Vac, 50/60Hz - OUT
12Vdc, 1.25A
• IN 230Vac, 50Hz - OUT 24Vac, 50Hz, 400mA
10.1.4 Environment
For indoors and outdoors installation
Operating temperature (with heater): From -20°C
(-4°F) up to +60°C (140°F)
Chemical agents resistance
• High resistance: basics, alcohols, gas,
hydrocarbon
• Good resistance: Organic acids, inorganic acids,
oils
• Low resistance: Solvents
10.1.5 Certifications
Electrical safety (CE): EN60950-1, IEC60950-1,
EN62368-1, IEC62368-1
Electromagnetic compatibility (CE): EN50130-4,
EN61000-6-3, EN55032 Class B, FCC Part. 15 Class B,
ICES-003 Class B
Outdoor installation (CE): EN60950-22, IEC 60950-22
IP protection degree (EN60529):
• IP66/IP67 (with cable glands)
• IP66/IP67 (with bracket with internal cable
channel, with sealing rings)
• IP55 (with bracket with internal cable channel)
• IP44 (for models with a double filter for air
renewal)
IK protection degree (EN62262): IK10
UL certification:
• cULus Listed, TYPE 4X (except for versions with
double filter for the air exchange)
• UL94, V1 (fire-self extinguish)
EAC certification
15