Attachment and alignment
1
Initially remove the protective foil from the back
of the extractor hood and, following installation,
remove foil completely.
2
Mount the extractor hood, ensuring that the
back is attached firmly to the brackets
3
Align the extractor hood horizontally by turning
the brackets..
If required, the extractor hood can be moved to
Ⓑ
the right or left
Locking screws and locking caps
1
Mark the holes for the safety screws. Detach
the extractor hood, drill holes for the safety
screws and press in wall plugs flush with the
wall.
2
Attach the extractor hood and screw in the
safety screws tightly.
3
Press the safety caps with the arrow upwards
onto the brackets until they click into
Ⓒ
position
.
Ⓐ
.
.
RISK OF INJURY
Check that all locking screws and locking caps
have been attached securely!
4
Connect the pipes (see "Connecting pipes").
5
Connect to the power supply (see "Electrical
connection").
Removing the safety caps
•
Remove the locking caps from the brackets
using a suitable tool, e.g. a flat-blade
screwdriver.
33