Temp (type-K)
4-20mA%
Note: Accuracy specifications consist of two elements:
• (% reading) – This is the accuracy of the measurement circuit
• (+ digits) – This is the accuracy of the analog to digital converter
Enclosure:
Shock (Drop Test):
Diode Test:
Continuity Check:
Peak:
Temperature Sensor:
Input Impedance:
AC Response:
AC True RMS:
ACV Bandwidth:
Crest Factor:
Display:
Overrange indication:
Auto Power Off:
Polarity:
Measurement Rate:
-58 to
1832°F
-50 to
1000°C
-25 to
0.01%
125%
0mA=-25%, 4mA=0%, 20mA=100%, 24mA=125%
Double molded, waterproof
6.5 feet (2 meters)
Test current of 0.9mA maximum, open circuit
voltage 2.8V DC typical
Audible signal will sound if the resistance is less
than 35Ω (approx.), test current <0.35mA
Captures peaks >1ms
Requires type K thermocouple
>10MΩ VDC & >3MΩ VAC
True RMS
The term stands for "Root-Mean-Square",
which represents the method of calculation of
the voltage or current value.
Average responding multimeters are calibrated
to read correctly only on sine waves and they
will read inaccurately on non-sine wave or
distorted signals. True rms meters read
accurately on either type of signal
50Hz to 1000Hz
≤3 at full scale up to 500V, decreasing linearly
to ≤1.5 at 1000V
40,000 count backlit liquid crystal with bargraph
"OL" is displayed
15 minutes (approximately) with disable feature
Automatic (no indication for positive); Minus (-)
sign for negative
2 times per second, nominal
reedinstruments
www
1°F
±(1.0% reading + 4.5°F)
±(1.0% reading + 2.5°C)
(probe accuracy not included)
1°C
±50 digits
continued ...