The Device works most efficiently when the
edge of the upper airing vent opening is
adjacent to the ceiling of the steam room
(model with a protective grille). If the De
vice is not equipped with a protective grille,
the Device should be installed so that the
upper edge remains 3–4 in. / 80–100 mm
below the ceiling. The lower edge may not
be closer than 4 in. / 100 mm. to the floor to
prevent the water on the floor from coming
into contact with the electrical wiring of the
Device.
Figure 1D – Saunum AirSolo 70 / 80 model
installation.
The Device is designed for wall mounting
using the hanging strips included in the
set. The wall in the installation spot must be
able to carry the weight of at least 77 lb /
35 kg and allow the supplied hanging strips
to be fastened with screws. The hanging
strips are attached to the wall of the steam
room, each with at least two screws. The
Device is then lifted onto the wall so that
both the upper and lower strips slide be
tween the strips attached to the back of the
Device.
1.
2.
25