4
NO REVERSE
PRE-
5
FLASHING
6
FOTOTEST
MASTER/
7
SLAVE
To carry out the memorization, leave DIP SWITCH 7 on OFF.
WITH LIMIT
SWITCHES:
8
SELECTION
TOWARDS OPENING
WITHOUT LIMIT
8
SWITCHES:
BACK JUMP
To change the position of Dip 8, the power must be disconnected. Once modified, rerun
the SetUp of the stroke
9-10-11
NOT USED
SENSITIVE
12
EDGE
6. MEMORIZATION PROCEDURE OF THE STROKE
WARNING: After powering the control panel, wait 2 seconds before you start performing the
adjustment operations and check:
- The Input connections: all green DL5, DL6, DL7, DL8 must be on steady.
- The mechanical stops of the automation must be installed and adjusted both in opening and
in closing [see motor instructions].
IMPORTANT: Carry out the first stroke memorization with the RAL trimmer positioned
fully turned counterclockwise (minimum deceleration speed).
PROCEDURE WITHOUT LIMIT SWITCHES INSTALLED:
1. Start the procedure with the gate at approx. 0.5 m from the mechanical opening stop.
2. Press without releasing the PROG button (6 sec. ca.) till the DL2 LED starts flashing (orange):
3. The automation starts to open slowly in search of the opening stop;
If the automation closes instead of opening, stop the run of the gate (by cutting
the photocells or closing the STOP contact), invert the motor polarity in the con-
trol unit terminals, take the gate at approx 0,5 m from the mechanical stop) and
restart the procedure from the beginning.
Make sure you don't stand near the automation during saving.
4. Once the opening stop is reached, the automation slowly starts closing in search of the closing stop;
the automation ignores the closing commands during opening and will close
On
according to the automatic closing time
Off the automation responds as established by dip switch No. 2.
On the pre-flashing function is enabled.
Off the pre-flashing function is disabled.
On the "photocell test" function is enabled.
the "photocell test" function is disabled.
Off
Note: to be used when the photocells are not used.
enables the MASTER mode in the master/slave configuration (see T-COMM
On
instructions).
enables the standard operation (single motor) or SLAVE mode in the mas-
Off
ter/slave configuration (see T-COMM instructions).
operation for leaf with opening to the left (operator side);
On
Attention: the limit switch LEDs (LFCA and LFCC) are inverted
Off operation for gate with opening to the right (gearmotor side);
once the mechanical stop of the closing maneuver is reached, the automa-
On
tion makes a slight movement in the opposite direction to avoid jamming
between the rack and the pinion. (Editable with TauApp)
Off function deactivated
On RESISTIVE SENSITIVE EDGE 8,2 KΩ (terminal No. 10).
NC CONTACT SENSITIVE EDGE ( terminal No. 10).
Off
Note: if not used, keep the DIP in the OFF position and bridge the ter-
minals 7-10